Dynex DSX Automated ELISA System

 4.999,00 excl. tax

Reserved

SKU: LM 13467 Category:
Description

The DYNEX DSX Automated ELISA System is a proven, fully- automated open system with a unique dispense synchronization that helps eliminate plate drift and achieve consistent results across four independent plate incubators. This helps to manage testing workload with reduced labor and walkaway capability to maximize lab personnel effciency.

System:

Number of Plates: 4
Sample Capacity: 96
Continuous Sample Loading: Yes
Sample Tube Size: 10 mm – 16 mm diameter, 40 mm – 100 mm height
Number of Reagents: Up to 24 (25 mL tubes)
Number of Standard/Control Bottles: 33 (1.5 mL vials)
Assays per Plate: 1 assay per strip or up to 12 assays per plate
Dilution Wells Capacity: Up to 192 deep-well strips (24 x 8)
Sample Tip Capacity: 432 (4 x 108)
Reagent Tip Capacity: 41 tips

Reader:

Photometric Range: 0.000 – 3.000 OD
Spectral Range: 405 nm – 690 nm
Filter Slots: 6 wavelength
Precision: ± 0.010 OD at 0.000 – 0.500 OD, < 1% CV at 0.501 – 2.000 OD, < 1.5% at 2.001 – 2.500 OD
Accuracy: ± 0.01 OD or 2.5%, (0.000 – 3.000 OD) whichever is greater
Read Time: < 10 seconds, single wavelength, < 20 seconds, dual wavelength

Washer:
Manifold Configuration: 8-way
Programmable Volumes: 50 µL – 999 µL
Wash Buffer Capacity: 4 wash bottles at 2.0 L, with level-sensing
Residual Wash Volume: < 3 μL per well with dual-axis sweep in a flat-bottom plate
Dispense Precision: ≤ 5% CV (with 300 μL in a 96 well plate)
Waste Container: 8 L with waste full sensor

Incubator:
Number of Incubators: 4
Temperature Range: RT + 7° C to 50° C
Temperature Accuracy: ± 1° C
Shaking: > 15 Hz periodic or continuous
Temperature Monitoring: Yes

Reagent:
Reagent Tip Size: 1,300 µL
Reagent Pipetting Volume: 25 μL – 1,000 µL
Reagent Pipetting Precision: ≤ 3% CV at 10 shots at any volume in operating range above 50 µL
Reagent Pipetting Accuracy: ± 2% of target volume at 50 µL or greater
in operating range (single-shot mode) 

Sample:
Sample Tip Size: 300 μL
Sample Pipetting Volume: 10 μL – 250 μL single-shot
25 μL – 100 μL multi-shot
Sample Pipetting Precision: ≤ 3% CV at any operating volume above 10 μL (single-shot mode)
Sample Pipetting Accuracy: ± 2% of target volume at any operating volume above 10 μL (single-shot mode)
Estimated Cycle Time for Sample
Pickup to Delivery on Plate: < 8 seconds
Time to Dispense: 19 minutes (typical), 50 μL of 96 samples to plate from sample tubes or deep-well plates
Sampling Time w/Dilutions: < 26 minutes (typical)
Dilution Range: 1 part in 190 one-stage dilution, 1 part in 36,100 two-stage dilution
Dimensions (WxDxH): 1060 x 910 x 800 mm
Weight: 136 kg