Agilent 1100 HPLC System
€ 13.999,00 excl. tax
Agilent 1100 system consisting of:
1x Agilent 1100 Degasser type G1379A
2x Agilent 1100 Isocratic Pump type G1310A
1x Agilent 1100 Variable Wavelength Detector type G1314A
1x Agilent 1100 Fluorescence Detector type G1321A
2x Solvent tray
Manual injector with 1 ml sample loop
Laptop
Agilent 1100 IsoPump:
Hydraulic system: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments
Flow range: 0.2 – 10.0 ml/min
Flow precision: < 0.3 % RSD (typically 0.15 %), based on retention time, at 1 ml/min
Pressure: Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min, Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min
Pressure pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar (147 psi)
Compressibility compensation: User-selectable, based on mobile phase compressibility
Recommended pH range: 1.0 – 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
Dimensions (HxWxD): 140 x 345 x 435 mm
Weight: 11 kg
Agilent 1100 VWD:
Detection type: Double-beam photometer
Light source: Deuterium lamp
Wavelength range: 190–600 nm
Short term noise (ASTM): ± 0.75 x 10-5 AU at 254 nm
Drift: 3 x 10-4 AU/hr at 254 nm
Linearity: > 2 AU (5%) upper limit
Wavelength accuracy: ± 1 nm Self-calibration with deuterium lines, verification with holmium oxide filter
Band width: 6.5 nm typical
Flow cell: 14-µl volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
Dimensions (HxWxD): 140 x 345 x 435 mm
Weight: 11 kg
Agilent 1100 FLD:
Detection type: Multi-signal fluorescence detector with rapid on-line scanning capabilities and spectral data analysis
Light source: Xenon flash lamp
Pulse frequency: 296 Hz for single signal mode, 74 Hz for spectral mode
Excitation monochromator: range; 200 – 700 nm and zero-order, bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 300 nm
Emission monochromator: range; 280 – 900 nm and zero-order, bandwith; 20 nm, monochromator; concave holographic grating F/1.6 blaze 400 nm
Spectrum acquisition: Excitaiotn or emmision spectra, scan speed; 28 ms per data point, step size; 1 – 20 nm
Wavelength characterisric: Repeatability; ±0.2 nm, accuracy; ±3 nm
Flow cell: 8 µl volume and 20 bar pressure, quartz
Dimensions (HxWxD): 135 x 345 x 435 mm
Weight: 11.5 kg
Weight | 0,0 kg |
---|---|
Warranty | 6 months |
Condition | Used, in good condition |
Brand | Agilent |