Agilent 1100 HPLC – Quat Pump, Autosampler, Column Compartment & DAD

Reserved

SKU: EXT 29919 Category:
Description

Agilent 1100 HPLC – Quat Pump, Autosampler, Column Compartment & DAD

The Agilent 1100 HPLC is a complete and versatile high-performance liquid chromatography (HPLC) configuration, consisting of a quaternary pump, vacuum degasser, standard autosampler, thermostated column compartment, and diode array detector (DAD). This configuration is suitable for a wide range of analytical HPLC applications and provides a reliable basis for reproducible chromatographic analyses.

The Agilent 1100 series is built from separate, mutually integrated modules. The combination of the G1311A Quaternary Pump, G1322A Vacuum Degasser, G1313A Standard Autosampler, G1316A Thermostated Column Compartment, and G1315B Diode Array Detector forms a complete HPLC setup for automated sample injection, temperature-controlled column conditions, and UV-Vis/DAD detection. System Configuration
Agilent 1100 Vacuum Degasser – G1322A

Four-channel vacuum degasser for removing dissolved gases from the mobile phase. The G1322A has a maximum flow of 10 mL/min per channel and is equipped with PTFE membranes.

Model: G1322A
Type: Vacuum Degasser
Number of channels: 4
Max. flow: 10 mL/min per channel
Dimensions (W × D × H): 345 × 435 × 80 mm
Weight: approx. 7.5 kg
Power supply: 100–120 / 220–240 VAC, 50/60 Hz
Power: approx. 30 VA
Agilent 1100 Quat Pump – G1311A

The G1311A Quaternary Pump is a four-channel high-pressure pump for low-pressure gradient HPLC. The pump is designed for accurate and reproducible delivery of the mobile phase.

Model: G1311A
Type: Quaternary Pump / QuatPump
Flow range: 0.001–10.000 mL/min
Max. Pressure: up to 400 bar at lower flow
Four solvent inlets
Double piston pump
Dimensions (W × D × H): 345 × 435 × 140 mm
Weight: approx. 11 kg
Power supply: 100–120 / 220–240 VAC, 50/60 Hz
Power: approx. 180 VA
Agilent 1100 Standard Autosampler – G1313A

The G1313A Standard Autosampler enables automatic sample injection and is suitable for routine and automated HPLC analyses.

Model: G1313A
Type: Standard Autosampler / ALS
Injection volume: 0.1–100 µL
Expandable injection volume with overfill
Standard capacity: up to 100 × 2 mL vials
Max. System pressure: approx. 400 bar

Automatic sample injection
Dimensions (W × D × H): 345 × 435 × 200 mm
Weight: approx. 14.2 kg
Power supply: 100–120 / 220–240 VAC, 50/60 Hz
Agilent 1100 Thermostatted Column Compartment – ​​G1316A

The G1316A Thermostatted Column Compartment (TCC) ensures a controlled and stable temperature of the HPLC column. This contributes to reproducible retention times and chromatographic results. Model: G1316A
Type: Thermostated Column Compartment
Temperature range: approx. 10 °C below ambient temperature to 80 °C
Temperature stability: ±0.15 °C
Capacity: up to 3 columns of 30 cm
Solvent pre-heating
Dimensions (W × D × H): 410 × 435 × 140 mm
Weight: approx. 10.2 kg
Power: approx. 320 VA
Agilent 1100 Diode Array Detector – G1315B

The G1315B Diode Array Detector (DAD) is a UV-Vis detector that can record full spectra in addition to chromatographic signals. This makes the detector suitable for both quantitative and qualitative analysis. Model: G1315B
Type: Diode Array Detector
Wavelength range: 190–950 nm
1024-element diode array
Wavelength accuracy: ±1 nm
Programmable gap width: 1 / 2 / 4 / 8 / 16 nm
Spectral acquisition: up to approx. 80 spectra/s
Dimensions (W × D × H): 345 × 435 × 140 mm
Weight: approx. 11.5 kg
Solvent Tray

The HPLC is supplied including a solvent tray, suitable for placing the mobile phase cylinders on top of the module stack.

Maintenance and condition

This Agilent 1100 HPLC has been maintained annually by Agilent Engineers.

Last maintenance: July 2026 – PASSED

With this, the most recent maintenance/inspection has been carried out successfully. This makes the configuration particularly interesting for laboratories that value a documented maintenance history. Dimensions

The individual modules have the following dimensions:

Module Dimensions W × D × H Weight
G1322A Vacuum Degasser 345 × 435 × 80 mm approx. 7.5 kg
G1311A Quat Pump 345 × 435 × 140 mm approx. 11 kg
G1313A Autosampler 345 × 435 × 200 mm approx. 14.2 kg
G1316A Column Compartment 410 × 435 × 140 mm approx. 10.2 kg
G1315B DAD 345 × 435 × 140 mm approx. 11.5 kg

The module dimensions are based on the Agilent 1100 Series specifications. Key benefits
Complete Agilent 1100 HPLC configuration
Quaternary pump for flexible mobile phase composition
Four-channel vacuum degassing
Automatic sample injection
Thermostat for controlled column temperature
Sensitive and versatile DAD detection
Includes solvent tray
Annual maintenance by Agilent Engineers
Last maintenance: July 2026 – PASSED
Suitable for a wide range of analytical HPLC applications

Supplied as a complete set: G1322A Vacuum Degasser + G1311A Quat Pump + G1313A Standard Autosampler + G1316A Thermostated Column Compartment + G1315B Diode Array Detector + solvent tray.

Specifications
Weight 0,0 kg