Waters Acquity UPLC System

 19.999,00 excl. tax

Not available

SKU: IC 13631 Category:
The ACQUITY UPLC System eliminates significant time and cost per sample from your analytical process while improving the quality of your results. By outperforming traditional or optimized HPLC, this technology allows chromatographers to work at higher efficiencies with a much wider range of linear velocities, flow rates, and backpressures.
UPLC Technology, which has been adopted successfully in laboratories around the world for the most demanding separations, is highly robust, dependable, and reproducible. What differentiates the holistic design of ACQUITY UPLC systems is Waters’ patented sub-2-μm hybrid particle chemistry, which offers significant benefits over today’s HPLC systems equipped with standard 5-μm particle chemistries.
The ACQUITY UPLC System, used on its own or paired with Waters optical and MS detection technologies, provides unique end-to-end solutions for all industries and applications, including: ADME screening, food safety, bioanalysis, clinical, metabolite identification, metabonomics, method development, opens access, and routine quality screens.
Since its invention, ACQUITY UPLC Technology has enabled analytical chemists to reach far beyond conventional HPLC separations.

System consists of:
Waters Acquity UPLC TUV Detector
Waters Acquity UPLC Sample Manager
Waters Acquity UPLC Binary Solvent Manager

TUV Detector
Wavelength range: 190 to 700 nm
Bandwidth: <5 nm
Wavelength accuracy: ±1.0 nm
Wavelength repeatability: ±0.1 nm
Single λ dry noise: <6 μAU (at 230 nm, 1-second digital filter, 30-second segments, 2-Hz data rate, medium shunt in place)
Dual channel noise (dry): 10.0 x 10-5 AU (measured at 230 nm, running at 230 to 280 nm with 2-second filter at 2-Hz data rate; dry, medium shunt in place)
Linearity: <5% at 2.5 AU, propylparaben at 257 nm
Drift: 5.0 x 10-4 AU/hr. max (ΔΤ = +2 °C/hr.) at 230 nm, after 1 hr. warmup, using medium shunt 
Sensitivity setting range: 0.0001 to 4.0000 AUFS
Filter setting range: Single-wavelength; 0.1 to 5.0 seconds, Dual-wavelength; 1 to 50 seconds
Lamp source: 30-W High Brightness Deuterium lamp, 0.5 nm aperture, pre-aligned, front accessible
Photodiodes: 2 silicon photodiodes (matched pair)
Second-order filter: Automatic for wavelengths > 370nm
Wavelength calibration filter: Erbium filter, used at startup or on demand
Nitrogen purge: Purge fitting present on optics bench
Path length: 10 mm
Cell volume: 0.5 μL
Pressure limit: 69 bar

Sample Manager
Number of sample plates: 2 x 48 position 2.00 mL vial plates
Number of sample injections: 1 to 99 injections per sample
Injection volume range: 0.1 to 50.0 µL, in 0.1µL increments, partial or full loop mode, 10 µL loop
Sample delivery precision (full loop injection mode): <0.3 RSD, full loop
Sample delivery precision (PLNO injection mode): <1% RSD within 20% to 75% of loop volume
Injector linearity: >0.999 coefficient of deviation (from 20% to 75%, partial loop overfill (PLNO mode))
Sample temperature control:4.0 to 40.0°C, settable in 0.1°C increments (assumes an ambient temperature of 25°C). At an ambient temperature of 21°C  or lower the sample manager will maintain the temperature of the sample compartment down to 4.0°C with a tolerance of -2.0/+6.0°C, when configured with the maximum number of vails
Injection cycle time: <15 sec between multiple injections with “load ahead” enabled, 30 sec with single weak wash, pressure assist mode
Sample probe: XYZZ based needle in needle design
Minimum sample required: 5 µL residual, using maximum recovery 2 mL vails(zero offset)
Wash solvents: Two degassed: strong solvent and weak solvent, programmable to suit application
Sample carryover: < 0.005% or < 2.000 nL, whchever is greater

Binary Solvent Manager
Number of solvents: Up to four, in any combination of two, A1 or A2 and B1 or B2.
Solvent conditioning: Vacuum degassing (six channel), one channel per solvent and two channels for Sample Manager wash solvents 
Operating flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments
Compressibility compensation: Automatic and continuous
Effective system delay volume: <120µL, independent of system backpressure
Plunger seal wash: Intergral, active, programmable
Gradient profiles: Eleven gradient curves (including linear, step, concave and convex)
Wet prime: Automatic
Maximum operating pressure: 15000 psi up to 1 mL/min, 9000 psi up to 2mL/min per pump, not more than 15000 psi total
Composition accuracy: ±0.5% absolute (full scale) from 5 to 95% of flow rates from 0.5 to 2.0 mL/min
Compositing precision: 0.15% RSD or ±0.04 min SD, whichever is greater, based on retention time
Flow precision: 0.075% RSD or ±0.02 min SD, six replicates, based on retention time or volumetric measures (0.500 to 2.000 mL/min)
Flow accuracy: ±1.0% at 0.5 mL/min with degassed methanol

Quote notes