Waters Acquity UPLC System

 19.999,00 excl. tax

Not available

SKU: LM 12250 Category:
The ACQUITY UPLC System eliminates significant time and cost per sample from your analytical process while improving the quality of your results. By outperforming traditional or optimized HPLC, this technology allows chromatographers to work at higher efficiencies with a much wider range of linear velocities, flow rates, and backpressures.
UPLC Technology, which has been adopted successfully in laboratories around the world for the most demanding separations, is highly robust, dependable, and reproducible. What differentiates the holistic design of ACQUITY UPLC systems is Waters’ patented sub-2-μm hybrid particle chemistry, which offers significant benefits over today’s HPLC systems equipped with standard 5-μm particle chemistries.
The ACQUITY UPLC System, used on its own or paired with Waters optical and MS detection technologies, provides unique end-to-end solutions for all industries and applications, including: ADME screening, food safety, bioanalysis, clinical, metabolite identification, metabonomics, method development, opens access, and routine quality screens.
Since its invention, ACQUITY UPLC Technology has enabled analytical chemists to reach far beyond conventional HPLC separations.

System consists of:
Waters Acquity UPLC PDA Detector
Waters Acquity UPLC Column Heater
Waters Acquity UPLC Sample Manager
Waters Acquity UPLC Binary Solvent Manager

PDA Detector
Wavelength range: 190 to 500 nm
Optical resolution: 1.2 nm
Digital resolution: 1.2, 2.4, 3.6, 4.8, 6.0, 7.2, 8.4, 9.6, 10.8, 12.0
Wavelength accuracy: ±1.0 nm
Wavelength repeatability: ±0.1 nm
Digital filter: Variable with data rate
Order filter: Fixed 340 nm to 500 nm
Noise (shunt in place of flow cell): 10 µAU, Peak to peak, 2 sec time constant, 30 sec interval at 230 nm, 3.6 nm digital resolution, 2 Hz,
in a 240 micron medium shunt cell, 60 minute warm-up time Noise (10 mm analytical flow cell) 14 µAU, Peak to peak, 2 sec time constant, 30 sec interval at 230 nm, 3.6 nm digital resolution, 2 Hz, 0.5 mL/min, 10/90 Acetonitrile/water, 60 minute warm-up time
Drift (medium shunt cell and 10 mm analytical flow cell): 1000 µAU/hour, 2 sec time constant, 30 sec interval at 230 nm, 3.6 nm digital resolution, 2 Hz, 60 minute warm-up time.
Linearity: < 5% at 2.0 AU, propylparaben series at 257 nm
Data rate: 1, 2, 5, 10, 20, 40, and 80

Column Heater
Column heater: Accommodates two columns, 20 to 150 mm length x 1.0 to 4.6 mm internal diameter
Column temperature control: 5.0°C above ambient to 90°C settable in 0.1°C increments
Column tracking: eCord Technology column information mangement tracks and arxhives usage history
Compartment temperature measurement accuracy: ±1.0°C
Compartment heating rate: Less than 15 minutes from 5.0°C above ambient to 40.0°C

Sample Manager
Number of sample plates: 2 x 48 position 2.00 mL vial plates
Number of sample injections: 1 to 99 injections per sample
Injection volume range: 0.1 to 50.0 µL, in 0.1µL increments, partial or full loop mode, 10 µL loop
Sample delivery precision (full loop injection mode): <0.3 RSD, full loop
Sample delivery precision (PLNO injection mode): <1% RSD within 20% to 75% of loop volume
Injector linearity: >0.999 coefficient of deviation (from 20% to 75%, partial loop overfill (PLNO mode))
Sample temperature control:4.0 to 40.0°C, settable in 0.1°C increments (assumes an ambient temperature of 25°C). At an ambient temperature of 21°C  or lower the sample manager will maintain the temperature of the sample compartment down to 4.0°C with a tolerance of -2.0/+6.0°C, when configured with the maximum number of vails
Injection cycle time: <15 sec between multiple injections with “load ahead” enabled, 30 sec with single weak wash, pressure assist mode
Sample probe: XYZZ based needle in needle design
Minimum sample required: 5 µL residual, using maximum recovery 2 mL vails(zero offset)
Wash solvents: Two degassed: strong solvent and weak solvent, programmable to suit application
Sample carryover: < 0.005% or < 2.000 nL, whchever is greater

Binary Solvent Manager
Number of solvents: Up to four, in any combination of two, A1 or A2 and B1 or B2.
Solvent conditioning: Vacuum degassing (six channel), one channel per solvent and two channels for Sample Manager wash solvents 
Operating flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments
Compressibility compensation: Automatic and continuous
Effective system delay volume: <120µL, independent of system backpressure
Plunger seal wash: Intergral, active, programmable
Gradient profiles: Eleven gradient curves (including linear, step, concave and convex)
Wet prime: Automatic
Maximum operating pressure: 15000 psi up to 1 mL/min, 9000 psi up to 2mL/min per pump, not more than 15000 psi total
Composition accuracy: ±0.5% absolute (full scale) from 5 to 95% of flow rates from 0.5 to 2.0 mL/min
Compositing precision: 0.15% RSD or ±0.04 min SD, whichever is greater, based on retention time
Flow precision: 0.075% RSD or ±0.02 min SD, six replicates, based on retention time or volumetric measures (0.500 to 2.000 mL/min)
Flow accuracy: ±1.0% at 0.5 mL/minwith degassed methanol

Incuding PC

Quote notes

Weight 0,0 kg
Warranty

6 months

Condition

Used, in good condition

Date of Manufacture

2009