Agilent Series 1100 HPLC System

 7.900,00 excl. tax

Not available

SKU: LM 10226 Category:
Description
System contains:
Autosampler
Autosampler thermostat
Isocratic pump
Column thermostat
Variable wavelength detector

Autosampler:

Pressure Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5900 psi)
GLP features: Early maintenance feedback (EMF), electronic records of
maintenance and errors
Communications: Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features: Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range: 0.1 – 100 µl in 0.1 µl increments 
Replicate injections: 1 – 99 from one vial
Precision: < 0.25% RSD from 5 – 100 µl, < 1% RSD 1 – 5 µl, variable volume
Minimum sample volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover: Typically < 0.1%, < 0.05% with external needle cleaning
Sample viscosity range: 0.2 – 50 cp
Sample capacity: 100 × 2-ml vials in 1 tray
Injection cycle time: Typically 50 s depending on draw speed and injection volume
Autosampler thermostat:
Temperature range: adjustable from 4 ° C to 40 ° C in 1 ° steps
Temperature accuracy at ambient temperatures <25 ° C and humidity <50%: – 1 ° C to + 4 ° C at a set point of 4 ° C
Temperature accuracy at ambient temperatures> 25 ° C and / or humidity> 50%: – 1 ° C to + 5 ° C at a set point of 4 ° C

Isocratic pump:

Hydraulic System: Dual piston in series pump with proprietary servo-controlled variable stroke drive, floating pistons and active inlet valve
Setable Flow Range: 0.2 — 10 ml/min, in 0.001 ml/min increments
Flow Precision: <0.07% RSD, or <0.02 min SD whatever is greater, based on retention time at constant room temperature
Flow Accuracy: ±1% or 10µl/min whatever is greater
Pressure: Operating range 0 — 400 bar up to 5 ml/min, Operating range 0 — 200 bar up to 10 ml/min
Pressure Pulsation: < 2 %amplitude (typically < 1 %), at 1 ml/min isopropanol, at all pressures > 10 bar
Compressibility Compensation: User-selectable, based on mobile phase compressibility
Recommended PH Range: 1.0 — 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Control and Data Evaluation: Agilent ChemStation for LC
Analog Output: For pressure monitoring, 2 mV/bar, one output
Communications: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional
Thermostat column compartment:
Temperature range: 10 degrees below ambient to 80 ° C, up to 80 ° C: flow rates up to 5 ml / min
Temperature stability: ± 0.15 ° C
Temperature accuracy: ± 0.8 ° C (± 0.5 ° C for calibration)
Column capacity: Three 30 cm
Warm up / cool down: 5 minutes from surroundings to 40 ° C, 10 minutes from 40 – 20 ° C
Dead volume: 3 μl
Communication: Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and close signals, LAN via other module series
Safety and maintenance: Extensive diagnostics, fault detection and display (via control module and Agilent ChemStation), leak detection, safe leak handling, leakage output signal for shutdown of the pump system. Low voltages in important maintenance areas.
Variable Wavelength Detector:
Detection type: Double-beam photometer
Light Source: Deuterium lamp
Wavelength Range: 190 – 600 nm
Short term noise (ASTM) Single and Multi-Wavelength: ± 0.75 × 10-5AU at 254 nm
Drift: 3 × 10-4AU/hr at 254 nm
Linear Absorbance range: > 2 AU (5%) upper limit
Wavelength accuracy: ± 1 nm
Slit width: 1, 2, 4 , 8, 16 nm
Band Width: 6.5 nm typical
Diode Width: < 1 nm
Flow Cell: 14-µl volume, 10-mm cell path length and 40 bar maximum pressure
Specifications
Weight 0,0 kg
Warranty

1 month

Condition

Demo