Agilent 1290 Infinity HPLC System

 24.999,00 excl. tax

Not available

SKU: LM 15839 Category:

The Agilent 1290 Infinity LC System is designed to offer the greatest flexibility for performing analytical liquid chromatography using all types of current and emergent column technologies. The 1290 Infinity LC has the widest range of operating parameters so that it can replicate method settings transferred in from any pre-existing analytical HPLC or UHPLC system available from any vendor. The Agilent 1290 Infinity LC System offers some radical new design concepts to achieve this objective and yet clearly shows the pedigree of well-engineered reliability that has made Agilent HPLC systems the most successful HPLC line available.

 

System consists of:

Agilent 1290 Infinity Diode Array Detector

Agilent 1290 Infinity Thermostatted Column Compartment

Agilent 1290 Infinity Binary Pump

Agilent 1290 Infinity Sampler

Agilent 1290 Infinity Thermostat

PC with Agilent Openlab Chemstation

 

Agilent 1290 Infinity Diode Array Detector:

 

Detection type: 1024-element photodiode array

Light source: Deuterium lamp

Wavelength range: 190 – 640 nm

Short term noise: < ± 3 x 10-6 AU at 230 nm/4 nm, typically < ± 0.6 x 10-6 AU/cm at 230 nm/4 nm

Drift: < 0.5 x 10-3 AU/hr at 230 nm

Linear absorbance range: > 2.0 AU (5 %) at 265 nm

Wavelength accuracy: ± 1 nm (After recalibration with deuterium lines)

Wavelength bunching: 2 – 400 nm, programmable in steps of 1 nm

Slit width: 1, 2, 4, 8 nm

Diode width: ~ 0.5 nm

Flow cell: Max-Light Cartridge Cell ( 10 mm, V(σ) 1.0 µL)

 

Agilent 1290 Infinity Thermostatted Column Compartment:

 

Temperature range: 10°C below ambient to 100°C (up to 80°C for flow rates up to 5 ml/min, up to 100 °C for flow rates up to 2.5 ml/min)

Temperature stability: ± 0.05°C

Temperature accuracy: ± 0.8°C (± 0.5°C with calibration)

Column capacity: 3x 30 cm

Warm-up/cool-down time: 5 min from ambient to 40°C, 10 min from 40 – 20°C

Dead volume: 1.6 µl low dispersion heat exchanger, 3 µl left heat exchanger, 6 µl right heat exchanger

 

Agilent 1290 Infinity Binary Pump:

 

Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power

transmission by ball screws, smooth motion control of pistons for active damping.

Settable flow range: 0.001—5 ml/min, in 0.001 ml/min

increments (executed in 300 pl/step increments)

Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2—5.0 ml/min)

Flow accuracy: ±1 % or 10 µl/min, whatever is greater

Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.

Pressure pulsation: <1 % amplitude or < 0.5 MPa (5 bar), whatever is greater

Compressibility compensation: Automatic, pre-defined, based on mobile phase selection.

Gradient formation: High pressure binary mixing.

Composition range: Settable range 0 – 100% (recommended range: 1 – 99% or 5 µl/min per channel, whatever is greater)

Composition precision: <0.15 % RSD, or 0.01 min SD, whatever is greater

Composition accuracy: ±0.35 % absolute (5 – 95 %, 0.2 – 5.0 ml/min)

Integrated degassing unit: 2 channels, internal volume per channel 1.5 mL

 

Agilent 1290 Infinity Sampler:

 

Injection range: 0.1 – 20 µL in 0.1 µL increments

Precision: <0.25 % RSD from 5 – 20 µL, <0.5 % RSD from 2 – 5 µL, <0.7 % RSD from 1 – 2 µL

Sample viscosity range: 0.2 – 5 cp

Sample capacity: 2 x 54 vials

Injection cycle time: <21 s using standard conditions

Carry over: <0.004 %

 

Agilent 1290 Infinity Thermostat:

 

Temperature range: Settable from 4°C to 40°C in 1° increments

Temperature accuracy (ambient temperatures < 25°C and humidity < 50 %): 3°C to 8°C at a setpoint of 4°C

Temperature accuracy (ambient temperatures <30°C and humidity <60 %): 3°C to 9°C at a setpoint of 4°C

Quote notes

Weight 0,0 kg
Warranty

6 months

Condition

Used, in good condition