The Waters 2487 Dual Absorbance Detector is a two-channel, tunable, ultraviolet/visible detector designed for high-performance liquid chromatography applications.
The detector uses newly designed optics with an enhanced illumination system for improved performance. These design features increase the optical throughput and sensitivity, and reduce bandwidth. This results in an overall increase in signal-to-noise ratio and improved linearity.
The Waters 2487 Dual λ Absorbance Detector has the following capabilities:
Stand-alone programmability – Stores up to 10 user-defined programs (or methods) consisting of up to 16 programmable timed events and 2 threshold events each.
Single or dual wavelength – Monitors absorbance at one or two discrete wavelengths.
Wavelength verification reference – Ensures wavelength accuracy.
Automatic second order filter – Automatically engaged for wavelengths 370 nm and greater and removed for wavelengths 369 nm or less.
Spectrum scan and storage – Supports spectrum scan, display, subtraction, storage, and playback, in addition to standard tunable absorbance and UV/Vis functionality.
Cuvette qualification – Facilitates qualification of the detector by insertion of a standard in a cuvette without breaking any fluidic connections. This feature also allows you to use the 2487 Detector as a benchtop spectrophotometer.
Cuvette sample analysis – Allows the spectrum of any sample placed in the cuvette to be recorded.
Method editing and storage – Supports basic method programming, storage, and retrieval from the front panel.
Full diagnostic capability – Supports built-in diagnostic tools to optimize functionality and performance.
Backward compatibility – Operates as a 486 Detector with PowerLine, Millennium32 software versions lower than 3.0, and other Waters products connected via the LAC/E interface using the IEEE-488 bus.
Two contact closure outputs – The 2487 Detector has two configurable switches, each of which can accommodate a maximum of +30 Vdc, 1.2 A current carry, and 0.5 A current switching. The switches (SW1 and SW2) can trigger fraction collectors and other external devices, as well as activate based on time, absorbance threshold, or ratio criteria.
Wavelength range: 190 to 700 nm
Bandwidth: 5 nm
Wavelength accuracy: +1 nm
Wavelength repeatability: +0.10 nm
Noise, single wavelength: < +0.35 x 10-5 AU, dry cell, 254 nm, 1.0 sec. time constant
Noise, dual wavelength: < +2.5 x 10-5 AU, dry cell, 254 nm / 280 nm, 2.0 sec. time constant
Linearity: 5% at 2.5 AU, propyl paraben, 257 nm
Drift: 1.0 x 10-4 AU/hour/° C at 254 nm (after 1 hour warmup)
Sensitivity setting range: 0.0001 to 4.0000 AUFS
Filter setting range:
– Single wavelength: 0.1 to 5.0 seconds, Hamming (default), 1 to 99 seconds, RC
– Dual wavelength: 1 to 50 seconds, Hamming (default), 1 to 99 seconds, RC
Lamp source: Deuterium arc lamp
Path length: 10 mm (standard analytical)
Cell volume: 10 µL (standard analytical)
Weight | 0,0 kg |
---|---|
Warranty | 6 months |
Condition | Used, in good condition |
Brand | Waters |